Laboratory for Ventilation, Air Quality and Safety
Lab activity
The laboratory is equipped to handle the following scientific operations: measuring of ventilation and climatic magnitudes in mines, tunnels and underground openings during excavation and exploitation; measuring of concentration of harmful and dangerous gases and dust in mines, tunnels, underground openings and communal waste dumps; calculation of ventilation network; design of ventilation for mines, tunnels and underground openings.
Head of the Lab: This email address is being protected from spambots. You need JavaScript enabled to view it., Prof., PhD.
Services:
- Measuring the concentration of dangerous and hazardous gasses in mines, tunnels, underground openings, work areas and waste dumps
- Measuring the dust concentration in mines, tunnels, underground openings, work areas and waste dumps
- Measuring the pressure drops along airways and ventilation ducts
- Design of ventilation for mines, tunnels and underground openings
Analytical procedure and test method
Analytical procedure |
Test method |
Measurements of gas concentrations in the atmosphere -O2, CH4, CO2, CO, NO, NO2, H2S, SO4, NH3
|
|
Measurements of microclimate parameters- air pressure, air temperature, air humidity
|
|
Air circulation speed measuring
|
|
Measuring the concentration of exhaust gases and particulate diesel engine
|
|
Measurements of dust emissions
|
|
|
Small and medium sized equipment
Name inventory |
Tech.characteristics |
Application |
Image |
Multiwarn II
|
SENSOR - RANGE O2 0 – 25 Vol% SO2 0 – 20 ppm C2H4O 0 – 50 ppm
|
Measurement of explosive and toxic gases in the air.
|
|
Multiwarn II
|
SENSOR - RANGE CO2 0 – 25 Vol% CH4 0 – 100 %LEL CO 0 – 500 ppm NO2 0 – 20 ppm NO 0 – 50 ppm
|
Measurement of explosive and toxic gases in the air.
|
|
Humidity tester
|
Temperature -10 do + 60 ºC Humidity 0 - 100 % RV The atmospheric pressure 800 -1100 hPa
|
Measurement of temperature, relative humidity and atmospheric pressure.
|
|
Termoanemometer
|
Speed of 0-30 m/s
|
The device for measuring the speed of air currents.
|
|
Digital manometer
|
Measuring range: -99,99...0...+99,99 mbar. Resolution 0,01 mbar. Max. the recording capacity 700.
|
The device for measuring the excess pressure, negative pressure and pressure difference.
|
|
An exhaust gas analyzer
|
Modul za plinove (EGA-8082) CO................. 0 do 9.99 % Res. 0.01 C02 ................ 0 do 19.9 % Res. 0.1 HC hexan........ 0 to 10000 PPM Res. 1 02...................... 0 to 100 % Res. 0.01 NO...................... 0 to 5000 PPM Res 10 Lambda.............. 0.5 to 2 - Res. 0.001
Module particles (SMO-300) Opacity............... 0 do 99.9 % Res. 0.1 Opacity ................ 0 do 9.99 m-1 Res. 0.01 Smoke temp......... 20 do 400 °C Res. 1
The meter speed and oil temperature (MGT-300) RPM.................... 300 do 9990 r/min Res. 10 Oil temp............... 20 do 200 °C Res. 1
|
Measurement of exhaust gas and particulate combustion engine.
|
|
|
Teaching in the laboratory (students' practical work)
Teaching in the laboratory (students' practical work) in 2016/2017
|
Course title
|
Mandatory or Elective course
|
Number of hours of practical work in lab
|
Number of students per group
|
Number of groups
|
Ventilation and Dewatering
|
Mandatory
|
8
|
27
|
1
|
Safety technique
|
Mandatory
|
8
|
39
|
1
|
|